Experience of selecting solutions to mitigate against the ignition hazards of static electricity in HAZLOC varies from those who are specifying static control solutions for the first time to those who specify solutions on a regular basis.
Although static electricity’s role in igniting potentially combustible atmospheres is generally less well known than sources like electrical or mechanical sparks, there are dedicated International Standards and Recommended Practices that can provide a broad overview of the kinds of processes that can be susceptible to electrostatic discharges.
Two publications that provide a broad overview of static electricity and its role as an ignition source in operations carried out in hazardous locations are NFPA 77 “Recommended Practice on Static Electricity” and IEC TS 60079-32-1 “Explosive Atmospheres, Electrostatic Hazards, Guidance”.
* This “Technical Specification” has been adopted by CENELEC and is referred to as IEC TS 60079-32-1 “Explosive atmospheres. Electrostatic hazards, guidance”.
While not every process capable of generating static electricity can be addressed in a single publication, the more commonly used metal objects used in industry, like tanker trucks, railcars, intermediate bulk containers (Ex IBCs), drums, or containers like Type C FIBCs, are addressed.
Generally speaking, grounding electrically conductive objects used in processes that are capable of generating an electrostatic charge prevents the accumulation of electrostatic charge by equalizing the potential difference of the object with respect to earth.
Section 3.3.23 of NFPA 77 2024ed states:
“3.3.23 Grounded (Grounding). Connected (connecting) to ground or to a conductive body that extends the ground connection.”
Section 13.1 of IEC TS 60079-32-1 states:
“13.1 General. By far the most effective method of avoiding hazards due to static electricity is to connect all conductors to earth. This will avoid the most common problem, which is the accumulation of charge on a conductor and the release of virtually all the stored energy as a single spark, to earth or to another conductor.”
If static charge is permitted to accumulate on an object (e.g., filling an electrically isolated metal drum), then a voltage rise is likely to develop whereby the voltage of the object exceeds the breakdown voltage of the atmosphere surrounding the point at which a static discharge could occur.
The primary hazard is that if the energy of the static discharge is higher than the Minimum Ignition Energies (MIE) of a combustible atmosphere that happens to be present at the location of the discharge, ignition could occur.
Newson Gale’s Grounding & Bonding Handbook identifies the processes at risk of discharging incendive electrostatic sparks into HAZLOC atmospheres.
The handbook includes:
The electrical resistance between the object to be grounded and the general mass of earth is the critical benchmark for grounding equipment used in processes that could result in electrostatic charge accumulation.
Although 1 megohm resistance to earth is generally accepted as a resistance level that is adequate for dissipating static electricity, both NFPA 77 and IEC TS 60079-32-1 state that a resistance higher than 10 ohms on a metal circuit (including the object to be grounded) can be indicative of loose, corroded, or broken connections.
Although many static grounding systems will monitor connection resistances that fall within a range of 1 megohm, a valid benchmark to set for a permissive condition could be to follow the recommendations of NFPA 77 or IEC TS 60079-32-1 of 10 ohms or less (R ≤ 10 Ω).
NFPA 77, 7.3.1.6.1 “Bonding and Grounding” states:
“Where the bonding/grounding system is all metal, resistance in continuous ground paths is measured to verify mechanical integrity. (See A.3.3.2) Such systems include those having multiple components. Greater resistance usually indicates that the metal path is not continuous, usually because of loose connections or corrosion…”
A.3.3.2 Bonding
“A resistance not exceeding 10 ohms for copper wire or 25 ohms for stainless steel or other metals is typically found in practice. Higher resistances could indicate a lack of mechanical integrity.”
13.2.2 “Practical Criteria” of IEC TS 60079-32-1:
“Metallic items in good contact with earth should have a resistance to it of less than 10 Ω. Although a value of up to 1 MΩ is acceptable for static dissipation, values above 10 Ω may give an early indication of developing problems (e.g. corrosion or a loose connection) and should be investigated. It is important that all connections are reliable, permanent and not subject to deterioration.”
Hence, the input criteria of a resistance of 10 ohms or less (R ≤ 10 Ω) can be defined as a primary condition for a grounding solution to indicate a positive connection between the object and the site’s verified ground.
The connection to the general mass of the earth can be achieved through the site’s electrical grounding and lightning protection circuits. Many sites also use dedicated, permanently installed, ground rods to provide a static dissipation path to earth.
Dedicated static grounding rods and electrical grounding and lightning protection circuits should be tested on a regular basis to ensure a low resistance connection to the general mass of the earth is maintained for the service life of such apparatus. Interconnecting conductors, e.g., busbars, should also be tested regularly to ensure a low resistance connection between the grounding point for process equipment and the verified ground.
NFPA 77, 7.3.1.6.1 “Bonding and Grounding” continues:
“… A permanent or fixed grounding system that is acceptable for power circuits or for lightning protection is more than adequate for a static electricity grounding system. Static grounds should be made to the building steel, if possible. Grounding to power grounds or lightning protection systems is not recommended.”
Section 13.4 of IEC TS 60079-32-1 “The establishment and monitoring of earthing systems”
13.4.1 Design
“Where the bonding/earthing system is all metal, the resistance in continuous earth paths typically is less than 10 Ω. Such systems include those having multiple components. A greater resistance usually indicates that the metal path is not continuous, usually because of loose connections or corrosion. An earthing system that is acceptable for power circuits or for lightning protection is more than adequate for a static electricity earthing system.”
Day-to-day static grounding and bonding tasks are normally performed by process operators or vehicle drivers. In order to help operators and drivers follow static grounding standard operating procedures (SOPs), a visual reference of a ground connection can be a good reminder not to start the process until the grounding status of the equipment has been confirmed.
This can support a “Clamp On First, Clamp Off Last” procedure by reminding operators that they should have a verifiable ground connection before they commence the process (e.g., filling an Ex IBC) and not remove the ground connection until the process has been completed.
Green flashing LEDs are commonly used to convey a “good to go” permissive situation. Flashing indicators can support the view that the grounding system is continuously monitoring the resistance of the connection to the equipment, indicating that the overall resistance in the “ground loop” between the object and the site’s verified ground is 10 ohms or less for the duration of the process.
If the ground connection resistance is higher than 10 ohms, the indicator will not go green. This could be an indication of wire connections loosening or breaking, or product deposits or paint coatings impeding a reliable electric connection to the equipment.
In combination with visual indication, grounding systems with output contacts can be utilized to add an extra layer of control. Such systems, normally incorporating voltage-free contacts (dry contacts) or intrinsically safe contacts, can be used to provide a permissive condition to equipment like pumps or PLCs when the grounding system input requirement (e.g., R ≤10 Ω resistance is established) is met.
This helps site managers to promote a policy of “Clamp On First, Clamp Off Last” with respect to static grounding SOPs, such that the process will not begin unless the grounding system has the necessary input(s) to provide a permissive output condition to the equipment controlling the movement of product.
It is essential that the Class and Division details of the location into which the equipment will be installed and operated is fully known prior to specifying static control equipment.
This ensures that the equipment protection techniques designed into the grounding system are 3rd party certified for use in that area.
There is no point in specifying HAZLOC-certified systems only for them not to be installed in accordance with the manufacturer’s instruction manual. Installations that do not reflect the manufacturer’s instruction manual risk invalidating the system’s certificate and use.
It is essential that the site owner or electrical contractor ensure that the installer has the appropriate competency level to install equipment certified for installation and use in a hazardous area.
From a certification standpoint, the instruction manual is a controlled document that will have been approved by the 3rd party certification body and should be reviewed before the installation begins.
Under no circumstances should the installation be attempted without first consulting the manufacturer’s instruction manual.
As operators will, for the majority of applications, be the people responsible for grounding or bonding equipment, it is essential that:
a) They are trained to understand why static electricity can pose an ignition risk for day-to-day operations.
b) They are trained on the correct use of static control equipment.
To do neither heightens the likelihood that they will not understand the inherent risks associated with electrostatic discharges.
If the process characteristics permit it, the principle of “Clamp On First, Clamp Off Last” can be embedded in the static grounding SOP.
Also, take a look at the level of control.
While the range of processes at risk of charge generation is too numerous to discuss, our Grounding & Bonding Handbook is a valuable resource.
It provides a general overview of some of the processes referred to in NFPA 77 and IEC TS 60079-32-1, along with further information on static electricity as a potential ignition source.
The Break Away Connector (BAC) is designed to address drive-offs during tanker trucks/tank trucks loading and unloading operations. To ensure safe product transfer, the grounding clamp must always be attached to the tanker truck before any other operations begin and securely stowed after all activities are completed. Failure to follow this procedure can result in the tanker truck driving off with part of the grounding system, causing costly damage and lengthy delays in restoring the safety system. The BAC mitigates this risk by allowing the grounding clamp and one-half of the connector to separate from the cable if a drive-off occurs, meaning only the clamp and connector need to be replaced to quickly restore the grounding system.
The Universal Resistance Tester (URT) is designed to provide users of Newson Gale Bond-Rite® static grounding systems with a means of testing the permissive resistance range on a regular basis.
The easy-to-use tester consists of a pair of rotary switches that enable a competent electrical person to check the resistance level at which the grounding system should be working and conduct a PASS/FAIL test at the required setting.
The Earth-Rite® II MGV Tester is a capacitance resistance tester (CRT) designed to have the same electrical characteristics as a tanker truck and provides engineers with a means of checking that the Earth-Rite® II MGV undergoing installation is permissive when it detects these characteristics.
The tester is connected to the Earth-Rite® II MGV system and its grounding point, and when activated, the Earth-Rite® II MGV’s LED indicators change from red to green, confirming that the Tanker Truck Recognition and Static Ground Verification checks are functioning as intended.
The CRT is highly recommended with a minimum of one per site.
• Required for system commissioning and routine service checks
• Easy to use with simple PASS/FAIL condition
Newson Gale’s R-series of static grounding reels offer Hytrel® cable housed on automatically retractable cable reel.
An optional stowage point is available for the VESX50-IP 2 pole magnetic grounding clamp. It allows the clamp to have a designated stowage point close to the item of ferrous metal based plant that the operator can use to stow the clamp safely when it is not in use.
Cen-Stat™ is a range of brightly coloured cables specially designed for applications in industrial and hazardous locations. Cen-Stat™ cables are based upon Hytrel® that combines the flexibility of rubber with the strength and process flexibility of thermoplastics.
Cables made from Hytrel® are mechanically resilient, have a wide working temperature and are resistant to a wide range of chemicals, as well as strong and durable.
The Cen-Stat™ range of FM and ATEX approved static grounding clamps and systems are designed to operate in the harshest hazardous locations. The certifications achieved by our range of clamps and cables benchmark their ability to establish and maintain good electrical contact with equipment requiring static grounding and bonding protection.
Equipment specifiers can order the Bond-Rite® CLAMP with 2-pole Cen-StatTM cable on standard spiral lengths of 10 ft (3 m), 16 ft (5 m), 32 ft (10 m) and 50 ft (15 m) of cable.
The spiral cable retracts when the clamp is not in use, ensuring the cable is neatly stowed and safely out of the way.
The Universal Resistance Tester (URT) is designed to provide users of Newson Gale Earth-Rite® static grounding systems with a means of testing the permissive resistance range on a regular basis.
The easy to use tester consists of a pair of rotary switches that enable a competent electrical person to check the resistance level at which the grounding system should be working and conduct a PASS/FAIL test at the required setting.
With this assembly operators tasked with grounding mobile process equipment will have a dedicated grounding point to attach the easy-to-use screw thread connector. The ‘plug-and-play connector can interface with all Newson Gale 2-core systems to provide ground monitoring capability on a wide range of mobile processes and equipment where generic grounding clamps cannot be used. The conical shape design aids in the reduction of powder deposit buildup over time and aids in clean-down operations.
A quick and easy-to-use grounding kit that may be swiftly deployed in an emergency or combustible material transfer operations where pre-existing designated grounding points are not available or accessible.
The portable grounding kit combines multiple shortened grounding rods (14 inches long) with surface wire grounding techniques to provide acceptably low resistance for static grounding requirements in field operations.
The flexible array of interconnected grounding rods is inserted into the soil at specified intervals to maximize the ability to safely dissipate static electricity from mobile trucks, service vehicles, and other equipment.
Static Grounding Canvas Kit Bag for Portable Grounding Kit and Cen-Stat™ Clamps, Assemblies, and Tools.
The strobe light is mounted in an elevated position and when the equipment is correctly grounded, flashes continuously informing personnel that a transfer process is underway and is protected from the static hazard. The strobe light can be used in conjunction with this product.
Designed for operating environments subject to intense sunlight, the ERII Sun Shield protects against direct sunlight hitting the indicators on the static grounding system.
The Sun Shield casts a shadow over the indicators during peak sunlight hours so that operators can easily view the ground status indicators. The shield is constructed from stainless steel and can be fitted to any installation in a matter of minutes.
The IS Switching PCB is an additional circuit board added to Newson Gale system enclosures, enabling users to directly interface with, and switch, intrinsically safe circuits without the need for additional equipment. The IS Switching PCB is designed not to affect the IS signal’s electrical parameters and is compatible with this product.
The retractable cable reel is supplied for grounding system installations where customers want to ensure the grounding clamp and cable are returned to the static grounding system by operators and drivers on completion of the material transfer process. The reel can be used in conjunction with this product.
The Earth-Rite® II RTR Tester is a capacitance resistance tester (CRT) designed to have the same electrical characteristics as a tanker truck/tank truck and provides engineers with a means of checking that the Earth-Rite® II RTR undergoing installation is permissive when it detects these characteristics.
The tester is connected to the Earth-Rite® II RTR system and its grounding point, and when activated, the Earth-Rite® II RTR’s LED indicators change from red to green, confirming that the Tanker Truck Recognition and Static Ground Verification checks are functioning as intended.
The CRT is highly recommended with a minimum of one per site.
• Required for system commissioning and routine service checks
• Easy to use with a simple PASS/FAIL condition